Comparative Study of Air Performance of Fully Ducted Damper for HVAC based on Different Blade Profiles

dc.contributor.authorPaudel, Gaurav
dc.date.accessioned2022-01-02T09:57:39Z
dc.date.available2022-01-02T09:57:39Z
dc.date.issued2021-03
dc.descriptionVolume control damper is a device for controlling and regulating the airflow into an indoor atmosphere and is one of the different fittings in a Heating Ventilation and Air Conditioning system.en_US
dc.description.abstractVolume control damper is a device for controlling and regulating the airflow into an indoor atmosphere and is one of the different fittings in a Heating Ventilation and Air Conditioning system. Airfoil damper blade is a best suited blade among the different damper blades in use, viz. airfoil, triple-V and flat. A comparative air performance analysis was done between same thickness blades, one is conventional airfoil and NACA0010, other being reduced thickness of airfoil shape of conventional airfoil and NACA0006 for different air velocities. Computational Fluid Dynamics analysis of all four cases were done in Ansys software as per American National Standards Institute and Air Movement and Control Association Standard 500D configuration 5.3. Pressure drop from conventional airfoil was compared with the data available in the American Society of Heating Refrigerating and Air-conditioning Engineers duct fitting database for different air velocities. From the analysis of four different airfoil profile, it was found out that 4-digit NACA0010 airfoil has least pressure drop of all, and hence is the best suited profile for the damper among the damper profiles considered in the analysis. Also, superiority of 4-digits NACA airfoil profile is observed to that of conventional airfoil with respect to their total pressure drop.en_US
dc.identifier.citationMASTER OF SCIENCE IN MECHANICAL SYSYTEMS DESIGN ENGINEERINGen_US
dc.identifier.urihttps://hdl.handle.net/20.500.14540/6946
dc.language.isoenen_US
dc.publisherPulchowk Campusen_US
dc.subjectHeating Ventilationen_US
dc.subjectAir Conditioningen_US
dc.titleComparative Study of Air Performance of Fully Ducted Damper for HVAC based on Different Blade Profilesen_US
dc.typeThesisen_US
local.academic.levelMastersen_US
local.affiliatedinstitute.titlePulchowk Campusen_US
local.institute.titleInstitute of Engineeringen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gaurav Paudel.pdf
Size:
6.38 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: